Sump Pump Repair, Replacement and Backup Systems
Repair, replacement and backup for the pit pumps that keep groundwater out of elevator shafts, garages and crawl spaces.
Sump Pump Repair and Installation in South Florida
A sump pump is a single point of failure with water on the other side of it. When it stops, the pit fills, and then whatever the pit was protecting starts taking water — an elevator shaft, a below-grade garage, a crawl space, the base of a wall. With a South Florida water table sitting a few feet below grade, a dead pump does not give you days. It gives you hours.
Most failures are not the pump motor. They are a float switch jammed against the basin wall, a check valve that has stopped holding so the discharge column falls back into the pit on every cycle, a discharge line that has silted up or been buried under landscaping, or a tripped GFCI receptacle nobody has looked at. Those are four separate faults with four separate fixes, and dropping in a new pump without establishing which one it was sells you a repeat.
The other half of the work is what happens when the power goes out, because in this region the day of maximum inflow and the day the grid fails are frequently the same day. One motor, on one circuit, with no alarm and no second pump, is a system that works right up until the moment it is needed.
The situations this service is for
- A pump that hums but does not move any water
- A pit that fills and overflows while the pump appears to be running
- A pump that restarts within seconds of shutting off
- A pump that never stops, even after the basin has emptied
- Water standing in an elevator pit, a below-grade garage or a crawl space that used to be dry
- A discharge line that gurgles, hammers or backfeeds into the pit
- A pump that has never been tested and a storm in the forecast
What is actually done, in order
- Test the pit before touching the pump
- The basin is bailed, the inflow rate timed, and the pump run manually to see whether it lifts water at all. A pump humming under load, a pump spinning against no head and a pump that has lost its impeller each behave differently, and that is established before any part is ordered.
- Float, switch and check valve first
- Tethered, vertical and electronic switches each fail in their own way, and a check valve that no longer seats sends the entire vertical discharge column back down the pipe on every shutdown. Both are proven before a pump is condemned, because both produce the same picture: a full pit and a motor that looks dead.
- Follow the discharge to daylight
- The line is traced from the check valve to wherever it terminates and confirmed to be flowing. A 1.5-inch discharge is not interchangeable with a 2-inch one, and buried outlets, crushed sections, silted ends and lines landscaped over after the fact are common here — all of them produce a pump running against a closed pipe.
- Size the replacement to the pit and the lift
- Selection comes from measured inflow and from vertical lift plus friction to the discharge point, not from the horsepower stamped on the old unit. Basin diameter and depth — an 18-inch liner behaves differently from a 24-inch one — determine switch travel and how many times an hour the motor is allowed to start.
- Backup, alarm and the circuit that feeds them
- A high-water alarm and a secondary pump, battery-driven or water-powered, are what carry the system through an outage. Bringing a dedicated circuit or a GFCI receptacle to the pit is electrical work: it is coordinated with a licensed electrical contractor rather than improvised at the pit edge.
- Prove it under water
- The basin is filled from a hose and the system run through complete cycles — primary pump, backup, alarm — with the discharge confirmed to be flowing outside the building rather than assumed. A pump that lifts water from a bailed pit can still fail on the float travel a full basin actually gives it.
What South Florida changes about this job
South Florida is not basement country, so the pumps here sit in different places than they do further north: elevator pits in the coastal mid-rise and high-rise buildings from Aventura up to Pompano Beach, below-grade parking in those same towers, crawl spaces under the older raised homes east of Federal Highway, and drainage basins tied to French drains and exfiltration trenches in the flatter inland neighborhoods of Davie, Plantation and Miramar. The water table across coastal Broward and Miami-Dade sits close enough to grade that these pits recharge from groundwater continuously rather than only when it rains, which means the pump is working on a dry afternoon in February and has been quietly wearing out all along. Then hurricane season puts peak inflow and grid outages on the same calendar, which is the entire argument for a second pump and a high-water alarm instead of one motor on one circuit.
- The electrical side is a separate trade. A pit pump needs a properly protected receptacle on a circuit that can carry the motor, and installing or altering that circuit is Florida electrical contractor work — better established when the job is scoped than on the morning of it.
- Elevator pits in mid-rise and high-rise buildings are association equipment with their own access rules, and what may be pumped out of them can be subject to an oil-water separator requirement before it reaches any receiving system. Coordination with the building and its elevator contractor runs ahead of any plumbing.
- A basin that also receives fixture waste is not a sump but a sewage ejector, which needs a sealed and vented cover and a pump built to pass solids. It is a different service and it is scoped as one rather than fitted with whatever the supply house had on the shelf.
- Where the discharge terminates is a drainage and code question as much as a plumbing one. A line dumping against a neighboring property, or into a system that was never designed to take it, simply relocates the problem.
- Anything that has spent its life in a wet pit tends to break on removal — a corroded union, a seized check valve, a discharge riser that has thinned from the inside. Scope on this job most often grows at the moment the old pump comes out of the basin.
Sump Pump Repair and Installation — straight answers
Why does my sump pump run constantly?
Two very different causes hide behind the same symptom. Either the inflow genuinely is that high — a high water table after sustained rain, a broken irrigation line nearby, or a failed check valve returning the same water to the pit on every cycle — or the switch is stuck closed and the pump is running in an empty basin. The second is the expensive one, because a pump with nothing to move overheats instead of pumping. Timing the cycle and watching whether the discharge column falls back separates the two in a few minutes.
The pump hums but no water moves. Is the motor gone?
Not necessarily. A hum under load with no flow usually means the impeller is jammed, the volute is packed with silt or gravel, or the discharge is blocked downstream so the pump is working against a closed pipe. A seized motor sounds different and normally trips the breaker instead. The order of checking is the discharge line first, then the impeller, then the motor — replacing the whole pump when the outlet was buried under sod solves nothing and hides the fault for another season.
Do I need a battery backup?
If the pit protects something that matters — an elevator shaft, a finished space, equipment — then a single pump on grid power is a system with one known failure mode and no warning attached to it. A secondary pump on a deep-cycle battery covers an outage. A water-powered backup covers it without a battery but draws on the potable supply, so it depends on available pressure and on the backflow protection that arrangement requires. A high-water alarm is the smallest part of the package, the part most often left out, and the only part that tells you before the water does.
How often should a sump pump be tested?
Before every wet season at minimum, and again after any long dry spell, because a pump that has not moved in months can seize and its switch can stick in place. Make it a real test: fill the basin with a hose until the float lifts, watch the pump cycle, confirm water is actually leaving the discharge outside, then trigger the backup and the alarm. Lifting the float by hand is not a test — it proves the motor turns and nothing else about the system.
What moves the cost of a sump pump job?
Physical variables, not the calendar. Whether a basin already exists or has to be cut and set. The depth and diameter of the pit, which govern switch type and pump body. The vertical lift to the discharge point and the run beyond it, which set the capacity needed. Whether the existing receptacle and circuit are correct, since bringing power to a pit is electrical contractor work carried by another trade. Whether the discharge legally terminates where it currently does. Whether a backup pump and a high-water alarm are in scope. And in a building, whether the pit is association equipment with scheduled access windows.
Can I replace a sump pump myself?
The plumbing side of a like-for-like swap is within reach of a competent homeowner. What catches people is everything around it: matching capacity to the actual lift rather than to the horsepower on the old label, seating a check valve in the right orientation and at the right height, and not gluing the discharge in a way that makes the next removal a cutting job. The electrical connection is a different trade with its own requirements, and the pit itself is a confined, wet, energized space.
What is the difference between a sump pump and a sewage ejector?
A sump pump moves clear groundwater and seepage. A sewage ejector moves fixture waste from a bathroom or laundry sitting below the gravity drain line, which means solids, a sealed and vented basin, and a pump built to pass them. They can look similar in a catalog and they are not interchangeable. Putting a sump pump into an ejector basin blocks it within weeks; putting an unsealed lid on an ejector basin puts sewer gas straight into the room it serves.
Why is there water in my elevator pit?
In a South Florida building it is usually groundwater through the pit wall or slab, which is exactly what the pit pump exists to handle — so water standing there means the pump, its float or its discharge has failed. It can also be a hydraulic line, a leaking supply riser, or condensate finding its way down the shaft, and those are different problems with different owners. The pit is association equipment: report it, stay out of it, and let access be arranged through the building alongside the elevator contractor rather than around them.
Where should the discharge line go?
Away from the building, and away from anywhere the water can find its way back to the pit. A short discharge dumping at the foundation creates a loop the pump can never win, and it presents as an inflow problem no basin was going to keep up with. Where a line may legally terminate depends on your municipality and on whether the receiving system is sanitary, storm or ground — across coastal Broward and Miami-Dade that call often sits with the drainage or utility authority rather than the building department, and it is confirmed for your address before a new line is routed.
My pump cycles on and off every few seconds. What is that?
The name for it is short cycling, and in a pit it has three usual sources: a check valve that is not holding, so the water standing in the vertical discharge falls straight back and re-triggers the float; a float set with too little travel for the depth of the basin; or a basin far too small for the inflow reaching it. Ten starts a minute is not a duty cycle any pit pump is built for, which is why the motor ends up the casualty rather than the cause. It is a valve and float fault far more often than a pump fault.